Intel® Arria® 10 Core Fabric and General Purpose I/Os Handbook

ID 683461
Date 10/25/2023
Public
Document Table of Contents

8.4.2. Error Detection Time

The time taken to detect the SEU error relative to the actual SEU event. This is determined by the device in use and the frequency of the error detection clock.

Table 114.  CRC Calculation Time in Arria® 10 Devices
  • Speed grade 1: N=1, 2 or 4.
  • Speed grade 2 and 3: N=2 or 4 only.
Variant Density Error Detection Time (ms)
GX/SX 160 / 220 14.29
270 / 320 14.29
480 21.13
570/ 660 27.84
GX/ GT 900 27.84
1150 44.28