External Memory Interfaces Intel® Stratix® 10 FPGA IP User Guide

ID 683741
Date 9/26/2022
Public
Document Table of Contents

13.7.5.4. Opening the Efficiency Monitor

The Efficiency Monitor GUI runs on the System Console. You can launch the System Console from the Tools menu in the Intel® Quartus® Prime software.

Connecting the Efficiency Monitor

  1. Compile a design with an Efficiency Monitor, as described in Enabling the Efficiency Monitor in a Design Example .
  2. Program the .sof file onto a device.
  3. Launch the System Console—either through the Intel® Quartus® Prime software, or directly from the command line.
  4. Load the .sof file of your design.
  5. Select the emif_effmon toolkit instance.
  6. Select EMIF Efficiency Monitor Toolkit in the Details section of the Toolkit Explorer in the System Console.
  7. Click Open Toolkit to launch the Efficiency Monitor toolkit.
Figure 163. Connecting the Efficiency Monitor

Starting and Stopping the Efficiency Monitor

To start collecting information on the Avalon® interface, click Enable Efficiency Monitor.

Figure 164. Enable Efficiency Monitor