External Memory Interfaces Intel® Stratix® 10 FPGA IP User Guide

ID 683741
Date 9/26/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

13.6.1.2. Evaluating SignaI Integrity Issues

Signal integrity problems can only really be evaluated in two ways:
  • direct measurement using suitable test equipment like an oscilloscope and probe
  • simulation using a tool like HyperLynx or Allegro PCB SI