7.7.3.2. Using Multiple Configuration Data
To configure multiple Cyclone® V devices in a chain using multiple configuration data, connect the devices to an EPCS or EPCQ device, as shown in the following figure.
When a device completes configuration, its nCEO pin is released low to activate the nCE pin of the next device in the chain. Configuration automatically begins for the second device in one clock cycle.