7.7.4. Estimating the Active Serial Configuration Time

The AS configuration time is mostly the time it takes to transfer the configuration data from an EPCS or EPCQ device to the Cyclone® V device.

Use the following equations to estimate the configuration time:

  • AS x1 mode

    .rbf Size x (minimum DCLK period / 1 bit per DCLK cycle) = estimated minimum configuration time.

  • AS x4 mode

    .rbf Size x (minimum DCLK period / 4 bits per DCLK cycle) = estimated minimum configuration time.

Compressing the configuration data reduces the configuration time. The amount of reduction varies depending on your design.