Intel® Hyperflex™ Architecture High-Performance Design Handbook
ID
683353
Date
10/04/2021
Public
A newer version of this document is available. Customers should click here to go to the newest version.
1. Intel® Hyperflex™ FPGA Architecture Introduction
2. Intel® Hyperflex™ Architecture RTL Design Guidelines
3. Compiling Intel® Hyperflex™ Architecture Designs
4. Design Example Walk-Through
5. Retiming Restrictions and Workarounds
6. Optimization Example
7. Intel® Hyperflex™ Architecture Porting Guidelines
8. Appendices
9. Intel® Hyperflex™ Architecture High-Performance Design Handbook Archive
10. Intel® Hyperflex™ Architecture High-Performance Design Handbook Revision History
2.4.2.1. High-Speed Clock Domains
2.4.2.2. Restructuring Loops
2.4.2.3. Control Signal Backpressure
2.4.2.4. Flow Control with FIFO Status Signals
2.4.2.5. Flow Control with Skid Buffers
2.4.2.6. Read-Modify-Write Memory
2.4.2.7. Counters and Accumulators
2.4.2.8. State Machines
2.4.2.9. Memory
2.4.2.10. DSP Blocks
2.4.2.11. General Logic
2.4.2.12. Modulus and Division
2.4.2.13. Resets
2.4.2.14. Hardware Re-use
2.4.2.15. Algorithmic Requirements
2.4.2.16. FIFOs
2.4.2.17. Ternary Adders
5.2.1. Insufficient Registers
5.2.2. Short Path/Long Path
5.2.3. Fast Forward Limit
5.2.4. Loops
5.2.5. One Critical Chain per Clock Domain
5.2.6. Critical Chains in Related Clock Groups
5.2.7. Complex Critical Chains
5.2.8. Extend to locatable node
5.2.9. Domain Boundary Entry and Domain Boundary Exit
5.2.10. Critical Chains with Dual Clock Memories
5.2.11. Critical Chain Bits and Buses
5.2.12. Delay Lines
2.2.2.1. Localized Clock Enable
The localized clock enable has a small fan-out. The localized clock enable often occurs in a clocked process or an always block. In these cases, the signal’s behavior is undefined under a particular branch of a conditional case or if statement. As a result, the signal retains its previous value, which is a clock enable.
To check whether a design has clock enables, view the Fitter Report > Plan Stage > Control Signals Compilation report and check the Usage column. Because the localized clock enable has a small fan-out, retiming is easy and usually does not cause any timing issues.