Arria V Device Handbook: Volume 1: Device Interfaces and Integration

ID 683213
Date 7/24/2020
Public
Document Table of Contents

11.8.1. Power Supplies Monitored and Not Monitored by the POR Circuitry

Table 122.  Power Supplies Monitored and Not Monitored by the Arria V POR Circuitry
Devices Power Supplies Monitored Power Supplies Not Monitored
Arria® V GX and GT
  • VCC_AUX
  • VCCBAT
  • VCC
  • VCCP
  • VCCPD
  • VCCPGM
  • VCCT_GXB
  • VCCH_GXB
  • VCCR_GXB
  • VCCA_GXB
  • VCCL_GXB
  • VCCA_FPLL
  • VCCD_FPLL
  • VCCIO
Arria® V GZ
  • VCC_AUX
  • VCCBAT
  • VCC
  • VCCPT
  • VCCPD
  • VCCPGM
  • VCCT_GXB
  • VCCH_GXB
  • VCCR_GXB
  • VCCA_GXB
  • VCCA_FPLL
  • VCCD_FPLL
  • VCCIO
  • VCCHIP
Arria® V SX and ST
  • VCC_AUX
  • VCCBAT
  • VCC
  • VCCP
  • VCCPD
  • VCCPGM
  • VCC_HPS
  • VCCPD_HPS
  • VCCRSTCLK_HPS
  • VCC_AUX_SHARED
  • VCCT_GXB
  • VCCH_GXB
  • VCCR_GXB
  • VCCA_GXB
  • VCCL_GXB
  • VCCA_FPLL
  • VCCD_FPLL
  • VCCIO
  • VCCIO_HPS
  • VCCPLL_HPS
Note: For the device to exit POR, you must power the VCCBAT power supply even if you do not use the volatile key.

Did you find the information on this page useful?

Characters remaining:

Feedback Message