DLL Range Specifications

Table 42.  DLL Frequency Range Specifications for Intel® Stratix® 10 Devices
Parameter Performance (for All Speed Grades) Unit
DLL operating frequency range 600 – 1,333 75 MHz
DLL reference clock input Minimum 600 MHz
75 In the SX device family, if the HPS EMIF is instantiated, the maximum speed for that instantiation is 1,066 MHz.