5.7. On-Chip I/O Termination in Stratix® V Devices

Dynamic RS and RT OCT provides I/O impedance matching and termination capabilities. OCT maintains signal quality, saves board space, and reduces external component costs.

The Stratix® V devices support OCT in all I/O banks.

Table 42.  OCT Schemes Supported in Stratix® V Devices
Direction OCT Schemes
Output RS OCT with calibration
RS OCT without calibration
Input RT OCT with calibration
RD OCT (differential LVDS I/O standard only)
Bidirectional Dynamic RS OCT and RT OCT