2.12.3.3. Link Fault Configuration
Offset: 0x405
Link Fault Configuration Fields
Bit | Name | Description | Access | Reset |
---|---|---|---|---|
3 | force_rf | Force the TX MAC to transmit Remote Faults when link fault signaling is on 1: TX MAC transmits Remote Faults 0: TX MAC operates normally |
RW | 0x0 |
2 | disable_rf | Send idles instead of remote faults for local faults in unidirectional mode 1: In unidirectional mode, local faults cause the TX to transmit Idles 0: In unidirectional mode, local faults cause the TX to transmit Remote Faults (spec default) |
RW | 0x0 |
1 | en_unidir | Enable Unidirectional Link Fault
1: EHIP enables support for unidirectional link fault signaling as described in Clause 66 Remote faults will have no impact on TX data, and Local faults will cause the TX to transmit Remote fault Ordered sets between frames
|
RW | 0x0 |
0 | en_lf | Enable Link Fault Reporting
1: The TX PCS will transmit link fault messages based on link faults detected by the RX
0: The TX PCS will not respond to link faults |