5.1.3.2. Early Pin Planning and I/O Assignment Analysis

The HPS clock input resides in the HPS Dedicated I/O Bank shared with I/O from HPS peripherals such as Ethernet, mass storage flash, and UART console. It's location within this bank is user configurable.

GUIDELINE: Choose an I/O voltage level for the HPS Dedicated I/O.