Video and Vision Processing Suite Intel® FPGA IP User Guide

ID 683329
Date 9/30/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents
1. About the Video and Vision Processing Suite 2. Getting Started with the Video and Vision Processing IPs 3. Video and Vision Processing IPs Functional Description 4. Video and Vision Processing IP Interfaces 5. Video and Vision Processing IP Registers 6. Video and Vision Processing IPs Software Programming Model 7. Protocol Converter Intel® FPGA IP 8. 3D LUT Intel® FPGA IP 9. AXI-Stream Broadcaster Intel® FPGA IP 10. Chroma Key Intel® FPGA IP 11. Chroma Resampler Intel® FPGA IP 12. Clipper Intel® FPGA IP 13. Clocked Video Input Intel® FPGA IP 14. Clocked Video to Full-Raster Converter Intel® FPGA IP 15. Clocked Video Output Intel® FPGA IP 16. Color Space Converter Intel® FPGA IP 17. Deinterlacer Intel® FPGA IP 18. FIR Filter Intel® FPGA IP 19. Frame Cleaner Intel® FPGA IP 20. Full-Raster to Clocked Video Converter Intel® FPGA IP 21. Full-Raster to Streaming Converter Intel® FPGA IP 22. Generic Crosspoint Intel® FPGA IP 23. Genlock Signal Router Intel® FPGA IP 24. Guard Bands Intel® FPGA IP 25. Interlacer Intel® FPGA IP 26. Mixer Intel® FPGA IP 27. Pixels in Parallel Converter Intel® FPGA IP 28. Scaler Intel® FPGA IP 29. Stream Cleaner Intel® FPGA IP 30. Switch Intel® FPGA IP 31. Tone Mapping Operator Intel® FPGA IP 32. Test Pattern Generator Intel® FPGA IP 33. Video Frame Buffer Intel® FPGA IP 34. Video Streaming FIFO Intel® FPGA IP 35. Video Timing Generator Intel® FPGA IP 36. Warp Intel® FPGA IP 37. Design Security 38. Document Revision History for Video and Vision Processing Suite User Guide

14.2. Clocked Video to Full-Raster Converter Parameters

Table 177.  Main Parameters
Parameter Values Description
Video Data Format
CV Bus Style Lite, CVI or CVO

Select which sideband signals the IP drives, and which signals are available in Platform Designer.

A second tab allows you to parameterize the CV bus style.

Bits per color sample 6 to 16 Number of bits per color sample.
Number of color planes 1 to 4 Number of color planes in a pixel.
Number of pixels in parallel 1, 2, 4 or 8 Number of pixels transmitted every clock.
AXI4S FR Bus has tReady connection True or False

Select true so the streaming full-raster interface contains the AXI4-S tReady signal.

Select false to remove, the tReady signal.

Control Settings
Memory-mapped control interface True or False Select True to turn on the CPU interface and associated signals. Select False to remove the CPU interface and for all the CPU registers to use default values.
Separate clock for control interface True or False

Select True to include the signal cpu_clock in Platform Designer. It is asynchronous to the video domain.

Select False so the CPU interface uses the signal vid_clock.

Dimensions
Max full-raster width 1 to 65535 The maximum width of raster that this IP passes.
Max full-raster height 1 to 65535 The maximum height of raster this IP passes.
Default full-raster width 1 to 65535

The width of the raster.

The CPU can override this value.

Default full-raster height 1 to 65535

The height of the raster.

The CPU can override this value.

Default Vsync H 1 to 65535

The default pixel position of the rising edge of the vertical timing signal (vsync or vblank)

The CPU can override this value.

Default Vsync V 1 to 65535

The default line where the rising edge of the vertical timing signal (vsync or vblank) occurs.

The CPU can override this value.

Figure 29. Main Parameters
Table 178.  CV Lite Parameters
Parameter Values Description
Parameters
Valid signal On or off When you select Lite the IP includes an optional data valid input signal, cv_vid_in_valid. Turn on to turn on this input in the IP. Platform Designer includes or removes the signal from the cv_vid_in conduit as appropriate.
Ready signal On or off When you select Lite the IP includes an optional data ready output signal, cv_vid_in_ready. Turn on to turn on this output in the IP. Platform Designer includes or removes the signal from the cv_vid_in conduit as appropriate.
Timing Signals sync, blank, or both Select which timing are available. Platform Designer includes or removes the signals from the cv_vid_in conduit as appropriate
Figure 30. CV Lite Parameters
Table 179.  CVI Parameters
Parameters Values Description
CVI Core Parameters
Source for total resolution Use Extra Logic or Use External Signals

The IP requires the height and width of the raster. Determine this information using additional logic within the IP, or get the information from optional input signals.

This parameter selects the source for the raster dimensions. Platform Designer includes or removes the signals from the cv_vid_in conduit as appropriate

CVI Legacy Tie Offs
Include the vid_hd_sdn signal True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Include the vid_std signal True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Width of vid_std 1 to 16 The width of the vid_std signal.
Include the hdmi_duplication signal True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Figure 31. CVI Parameters
Table 180.  CVO Parameters
Parameters Values Description
CVO Legacy Tie Offs
Drive CV Output Clock True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Include the underflow signal True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Include the vid_mode_change signal True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Include the frame lock signals True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Include the vid_std signal True or False Select True to add this signal to the cv_vid_in conduit. The signal has no function within the IP and is included for connectivity within Platform Designer.
Width of vid_std 1 to 16 Select the width of the vid_std signal.
Figure 32. CVO Parameters