Agilex™ 7 FPGAs and SoCs Device Data Sheet: F-Series and I-Series

ID 683301
Date 4/01/2024
Public
Document Table of Contents

E-Tile Transceiver Power Supply Recommended Operating Conditions

Table 8.  E-Tile Transceiver Power Supply Recommended Operating Conditions For specification status, see the Data Sheet Status table
Symbol Description Typical DC Level (V) Recommended DC Setpoint (% of Vnominal) Recommended VR Ripple (% of Vnominal) Recommended AC Transient (% of Vnominal) Maximum (DC Setpoint + Ripple + AC Transient) (% of Vnominal) Unit
VCCRT_GXE 15 Transceiver power supply 0.9 ± 0.5% ± 2.5% ± 3% V
VCC_HSSI_GXE E-tile digital signal power supply 0.9 ± 0.5% ± 2.5% ± 3% V
VCCRTPLL_GXE 15 Transceiver PLL power supply 0.9 ± 0.5% ± 2.5% ± 3% V
VCCH_GXE Analog power supply 1.1 ± 0.5% ± 0.5% ± 2% ± 3% V
VCCCLK_GXE LVPECL REFCLK power supply 2.5 ± 0.5% ± 0.5% ± 3.5% ± 5% V
15 The difference between VCCRT/VCCRTPLL and VCCH should be no less than 200 mV.