Altera® Quartus® Prime Standard Edition Settings File Reference Manual

ID 683084
Date 5/08/2017
Public
Document Table of Contents

1.2.84. MAX7000_FANIN_PER_CELL

Specifies the maximum fan-in per macrocell. Legal integer values, in percentage terms, range from 20 through 100.

Old Name

Maximum Fan-in Per Macrocell -- MAX 7000B/7000AE/3000A/7000S/7000A

Type

Integer

Device Support

  • MAX3000A
  • MAX7000A
  • MAX7000AE
  • MAX7000B
  • MAX7000S

Notes

This assignment is included in the Analysis & Synthesis report.

This assignment supports synthesis wildcards.

Syntax


		set_global_assignment -name MAX7000_FANIN_PER_CELL <value>
		set_global_assignment -name MAX7000_FANIN_PER_CELL -entity <entity name> <value>
		set_instance_assignment -name MAX7000_FANIN_PER_CELL -to <to> -entity <entity name> <value>
	

Default Value

100

Example


		set_global_assignment -name max7000_fanin_per_cell 20
		set_instance_assignment -name max7000_fanin_per_cell 20 -to foo