Altera® Quartus® Prime Standard Edition Settings File Reference Manual

ID 683084
Date 5/08/2017
Public
Document Table of Contents

1.10.250. PHYSICAL_SYNTHESIS_COMBO_LOGIC_FOR_AREA

Specifies that the Fitter should perform physical synthesis optimizations on combinational logic during fitting to achieve a fit. This feature is not supported in Quartus Prime Pro Edition.

Type

Boolean

Device Support

  • Arria GX
  • Arria II GX
  • Arria II GZ
  • Arria V
  • Arria V GZ
  • Cyclone 10 LP
  • Cyclone II
  • Cyclone III
  • Cyclone III LS
  • Cyclone IV E
  • Cyclone IV GX
  • Cyclone V
  • MAX 10
  • Stratix II
  • Stratix II GX
  • Stratix III
  • Stratix IV
  • Stratix V

Notes

This assignment supports Fitter wildcards.

This assignment is included in the Fitter report.

This assignment supports synthesis wildcards.

Syntax


		set_global_assignment -name PHYSICAL_SYNTHESIS_COMBO_LOGIC_FOR_AREA <value>
		set_global_assignment -name PHYSICAL_SYNTHESIS_COMBO_LOGIC_FOR_AREA -entity <entity name> <value>
		set_instance_assignment -name PHYSICAL_SYNTHESIS_COMBO_LOGIC_FOR_AREA -to <to> -entity <entity name> <value>
	

Default Value

Off