Altera® Quartus® Prime Standard Edition Settings File Reference Manual

ID 683084
Date 5/08/2017
Public
Document Table of Contents

1.10.29. CLOCK_ENABLE_ROUTING

Specifies whether a clock enable signal in an I/O cell should be driven by the peripheral bus or the single-pin path. The Single-Pin setting drives the clock enable signal with the local interconnect shared by the I/O cell and the adjacent LAB. The Peripheral setting drives the clock enable signal with a peripheral control bus. This option is ignored if it is assigned to anything other than a logic function assigned to an I/O cell or the signal that drives the clock enable of the I/O cell.

Type

Enumeration

Values

  • Peripheral
  • Single-Pin

Device Support

  • A
  • E

Notes

None

Syntax


		set_instance_assignment -name CLOCK_ENABLE_ROUTING -to <to> -entity <entity name> <value>