14.2. Control Synchronizer Parameter Settings

Table 44.   Control Synchronizer Parameter Settings
Parameter Value Description
Bits per pixel per color plane 4-20, Default = 8 Select the number of bits per pixel (per color plane).
Number of color planes 1–4, Default = 3 Select the number of color planes that are sent over one data connection. For example, a value of 3 for R'G'B' R'G'B' R'G'B' in serial.
Color planes are in parallel On or Off
  • Turn on to set colors planes in parallel.
  • Turn off to set colors planes in series.
Trigger on width change On or Off Turn on to start transfer of control data when there is a change in width value.
Trigger on height change On or Off Turn on to start transfer of control data when there is a change in height value.
Trigger on start of video data packet On or Off Turn on to start transfer of control data when the core receives the start of video data packet.
Require trigger reset via control port On or Off Turn on to disable the trigger once triggered. If you turn on this parameter, you need to enable the trigger using the control port.
Maximum number of control data entries 1–10, Default = 3 Specify the maximum number of control data entries that can be written to other cores.