7.5.7. Using the Design Service
Load
When you open System Console from the Intel® Quartus® Prime software, the current project's debug information is sourced automatically if the .sof file is present. In other situations, you can load the .sof manually.
set sof_path [file join project_dir output_files project_name.sof]
set design [design_load $sof_path]
System Console is now aware of the .sof loading.
Linking
Once a .sof loads, System Console automatically links design information to the connected device. The link persists and you can unlink or reuse the link on an equivalent device with the same .sof.
You can perform manual linking as follows:
set device_index 0; # Device index for our target
set device [lindex [get_service_paths device] $device_index]
design_link $design $device
Manual linking fails if the target device does not match the design service.