External Memory Interfaces Stratix® 10 FPGA IP User Guide

ID 683741
Date 11/28/2024
Public
Document Table of Contents

13.7.2.3. Launching the EMIF Debug Toolkit

Before launching the EMIF Debug Toolkit, ensure that you have configured your device with a programming file that has the EMIF Debug Toolkit enabled, as described in Configuring the EMIF IP and Calibration IP for Use with the Debug Toolkit.

To launch the EMIF Debug Toolkit, follow these steps:

  1. In the Quartus® Prime software, open the System Console by clicking Tools > System Debugging Tools > System Console.
  2. In the System Console, load the .sof file with which you programmed the board in Prerequisites for Using the EMIF Unified Calibration Debug Toolkit.
    Figure 125. 
  3. Select the correct instances to debug.
    Figure 126. 
  4. Open the toolkit.
    Figure 127. 
  5. If there are multiple EMIF instances in the programmed design, select the column (path to JTAG master) and ID of the EMIF instance for which to activate the toolkit.
    Figure 128. 
  6. Click Activate Interface to allow the toolkit to read the parameters and status of the selected interface, and to run analysis tasks.
    Figure 129. 
  7. You must debug the interfaces one at a time; therefore, when trying to connect to another EMIF in the design, you must deactivate the current interface.
    Figure 130.