4.2.4. STATUS_INPUT Command Description

The STATUS_INPUT command returns one byte of information, detailing the warning and failure conditions present on the input rail. These status bits remain set until cleared, which is accomplished by writing a '1' to that bit position, or issuing the CLEAR_STATUS command.
Table 13.   STATUS_INPUT Command Description
Bit Name Description
7 VIN_OV_FAULT An overvoltage fault occurred on the input rail.
6 VIN_OV_Warning The input rail is above the overvoltage warning level.
5 VIN_UV_Warning The input rail is below the undervoltage warning level.
4 VIN_UV_FAULT An undervoltage fault occurred on the input rail.
3 Reserved Unused
2 Reserved Unused
1 Reserved Unused
0 Reserved Unused