Intel® Quartus® Prime Pro Edition User Guide: Debug Tools

ID 683819
Date 12/12/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

3.4.6.6. Specify Trigger Position

You can specify the amount of data the logic analyzer acquires before and after a trigger event. Positions for Runtime and Power-Up triggers are separate.

The Signal Tap logic analyzer offers three pre-defined ratios of pre-trigger data to post-trigger data:

  • Pre—saves signal activity that occurred after the trigger (12% pre-trigger, 88% post-trigger).
  • Center—saves 50% pre-trigger and 50% post-trigger data.
  • Post—saves signal activity that occurred before the trigger (88% pre-trigger, 12% post-trigger).

These pre-defined ratios apply to both non-segmented buffers and each segment of a buffer.