External Memory Interfaces Cyclone® 10 GX FPGA IP User Guide

ID 683663
Date 11/28/2024
Public
Document Table of Contents

8.1.1.2.1. Read Capture

Read capture timing analysis indicates the amount of slack on the DQ signals that are latched by the FPGA using the DQS strobe output of the memory device.

The Timing Analyzer analyzes read capture timing paths through conventional static timing analysis and further processing steps that account for memory calibration (which may include pessimism removal) and calibration uncertainties as shown in the following figure.

Figure 68. Read Capture Timing Analysis

Cyclone 10 Read capture