External Memory Interfaces Cyclone® 10 GX FPGA IP User Guide

ID 683663
Date 4/01/2024
Public
Document Table of Contents

4.1.1.26. ctrl_auto_precharge for DDR3

Controller auto-precharge interface

Table 34.  Interface: ctrl_auto_prechargeInterface type: Conduit
Port Name Direction Description
ctrl_auto_precharge_req Input When asserted high along with a read or write request to the memory controller, indicates that the controller should close the currently opened page after the read or write burst.