4.1.1. MAC Synchronous Clock Connections to Single Instance
4.1.2. MAC Synchronous Clock Connections to Multiple Instances
4.1.3. Clock Connections to MAC Asynchronous Operation
4.1.4. Clock Connections in PTP-Based Synchronous Operation
4.1.5. Clock Connections in Synchronous Ethernet Operation (Sync-E)
4.1.6. I/O PLL as System PLL
4.8. Precision Time Protocol Interface
The Precision Time Protocol (PTP) interface is available when you select the Enable IEEE 1588 PTP option in the PTP tab. When selected, the IP generates PTP based 1-step or 2-step TX and RX timestamps. The IP requires the IEEE 1588 96-bit time-of-day (TOD) input.
Port Name | Width | Domain | Description |
---|---|---|---|
i_clk_tx_tod | 1 | N/A | Clock associated with TX Time-of-Day input. Frequency: 10GE: 156.25 MHz 25GE: 390.625 MHz |
i_clk_rx_tod | 1 | - | Clock associated with RX Time-of-Day input. Frequency: 10GE: 156.25 MHz 25GE: 390.625 MHz |
i_clk_ptp_sample | 1 | - | Sample clock for PTP measurement. Single sample clock source can be shared by all PTP logics within a Agilex™ 5 device. Frequency: 114.2857 MHz (Required period = 8.750 ns) |