PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide

ID 683716
Date 1/12/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

3.5.2. Reference Clock

Intel recommends that you source the reference clock to the PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel Agilex® 7 F-Series and I-Series devices from a dedicated clock pin. Use the clock pin in the I/O sub-bank with the following command:
set_location_assignment <PIN_NUMBER> -to <pll_ref_clock_signal_name>