Visible to Intel only — GUID: sfc1599793483439
Ixiasoft
1. About the PHY Lite for Parallel Interfaces IP
2. PHY Lite for Parallel Interfaces Intel® FPGA IP (phylite_ph2) for Intel Agilex® 7 M-Series Devices
3. PHY Lite for Parallel Interfaces Intel® FPGA IP (altera_phylite_s20) for Intel Agilex® 7 F-Series and I-Series Devices
4. PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel® Stratix® 10 Devices
5. PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel® Arria® 10 and Intel® Cyclone® 10 GX Devices
6. PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide Document Archives
7. Document Revision History for the PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide
3.2.1. Intel Agilex® 7 F-Series and I-Series I/O Sub-bank Interconnects
3.2.2. Intel Agilex® 7 F-Series and I-Series Input DQS/Strobe Tree
3.2.3. PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel Agilex® 7 F-Series and I-Series Devices Top Level Interfaces
3.2.4. Dynamic Reconfiguration
3.2.5. I/O Timing
4.5.6.4.1. Timing Closure: Dynamic Reconfiguration
4.5.6.4.2. Timing Closure: Input Strobe Setup and Hold Delay Constraints
4.5.6.4.3. Timing Closure: Output Strobe Setup and Hold Delay Constraints
4.5.6.4.4. Timing Closure: Non Edge-Aligned Input Data
4.5.6.4.5. I/O Timing Violation
4.5.6.4.6. Internal FPGA Path Timing Violation
5.5.6.4.1. Timing Closure: Dynamic Reconfiguration
5.5.6.4.2. Timing Closure: Input Strobe Setup and Hold Delay Constraints
5.5.6.4.3. Timing Closure: Output Strobe Setup and Hold Delay Constraints
5.5.6.4.4. Timing Closure: Non Edge-Aligned Input Data
5.5.6.4.5. I/O Timing Violation
5.5.6.4.6. Internal FPGA Path Timing Violation
Visible to Intel only — GUID: sfc1599793483439
Ixiasoft
4.3.2.1. Clock and Reset Interface Signals
Signal Name | Direction | Width | Description |
---|---|---|---|
ref_clk | Input | 1 | Reference clock for the PLL. The reference clock must be synchronous with strobe_in to ensure the dqs_enable signal is in-sync with strobe_in. |
reset_n | Input | 1 | Resets the interface. This signal is asynchronous. |
interface_locked | Output | 1 | Interface locked signal from PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel® Stratix® 10 devices to core logic. This signal indicates that the PLL and PHY circuitry are locked. Data transfer should starts after the assertion of this signal. |
core_clk_out | Output | 1 | Use this core clock in the core-to-periphery transfer of soft logic data and control signals. The core_clk_out frequency depends on the interface frequency and clock rate of user logic parameter. |
pll_extra_clock[0..3] | Output | 4 | These are the additional output clock signals generated by PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel® Stratix® 10 devices when you enable Specify additional output clocks based on existing PLL parameter. |
pll_locked | Output | 1 | This is the locked signal for the additional output clocks generated by the IP. |