PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide

ID 683716
Date 1/12/2024
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

2.2.2.1. Calibration IP

The Calibration IP provides access to the IOPLL and PHY registers through the AXI4-Lite IP interface. You can connect the Calibration IP to up to two periphery interfaces and three PLLs.

You must connect PHY Lite IP instances in different I/O banks to different Calibration IPs.

Connect PHY Lite IP instances in the same I/O bank to the same Calibration IP, but assign different Instance ID in the IP Parameter Editor to differentiate the base address of the instances (Rev B only).

Table 11.  ARM AMBA* AXI4-Lite IP Interface SignalsThis table describes the ARM AMBA* AXI4-Lite IP Interface signals.
Signal Name Direction Width Description
fbr_axil_clk Input 1 Clock
fbr_axil_rst_n Input 1 Reset
fbr_axil_awaddr Input 27 Write address
fbr_axil_awvalid Input 1 Write address valid
fbr_axil_awready Output 1 Write address ready
fbr_axil_wdata Input 32 Write data
fbr_axil_wstrb Input 4 Write strobes
fbr_axil_wvalid Input 1 Write valid
fbr_axil_wready Output 1 Write ready
fbr_axil_bresp Output 2 Write response
fbr_axil_bvalid Output 1 Write response valid
fbr_axil_bready Input 1 Response ready
fbr_axil_araddr Input 27 Read address
fbr_axil_arvalid Input 1 Read address valid
fbr_axil_arready Output 1 Read address ready
fbr_axil_rdata Output 32 Read data
fbr_axil_rresp Output 2 Read response
fbr_axil_rvalid Output 1 Read valid
fbr_axil_rready Input 1 Read Ready
fbr_axil_awprot Input 3 Write protection type
fbr_axil_arprot Input 3 Read protection type