PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide
ID
683716
Date
1/12/2024
Public
A newer version of this document is available. Customers should click here to go to the newest version.
1. About the PHY Lite for Parallel Interfaces IP
2. PHY Lite for Parallel Interfaces Intel® FPGA IP (phylite_ph2) for Intel Agilex® 7 M-Series Devices
3. PHY Lite for Parallel Interfaces Intel® FPGA IP (altera_phylite_s20) for Intel Agilex® 7 F-Series and I-Series Devices
4. PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel® Stratix® 10 Devices
5. PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel® Arria® 10 and Intel® Cyclone® 10 GX Devices
6. PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide Document Archives
7. Document Revision History for the PHY Lite for Parallel Interfaces Intel® FPGA IP User Guide
3.2.1. Intel Agilex® 7 F-Series and I-Series I/O Sub-bank Interconnects
3.2.2. Intel Agilex® 7 F-Series and I-Series Input DQS/Strobe Tree
3.2.3. PHY Lite for Parallel Interfaces Intel® FPGA IP for Intel Agilex® 7 F-Series and I-Series Devices Top Level Interfaces
3.2.4. Dynamic Reconfiguration
3.2.5. I/O Timing
4.5.6.4.1. Timing Closure: Dynamic Reconfiguration
4.5.6.4.2. Timing Closure: Input Strobe Setup and Hold Delay Constraints
4.5.6.4.3. Timing Closure: Output Strobe Setup and Hold Delay Constraints
4.5.6.4.4. Timing Closure: Non Edge-Aligned Input Data
4.5.6.4.5. I/O Timing Violation
4.5.6.4.6. Internal FPGA Path Timing Violation
5.5.6.4.1. Timing Closure: Dynamic Reconfiguration
5.5.6.4.2. Timing Closure: Input Strobe Setup and Hold Delay Constraints
5.5.6.4.3. Timing Closure: Output Strobe Setup and Hold Delay Constraints
5.5.6.4.4. Timing Closure: Non Edge-Aligned Input Data
5.5.6.4.5. I/O Timing Violation
5.5.6.4.6. Internal FPGA Path Timing Violation
2.2.2.1. Calibration IP
The Calibration IP provides access to the IOPLL and PHY registers through the AXI4-Lite IP interface. You can connect the Calibration IP to up to two periphery interfaces and three PLLs.
You must connect PHY Lite IP instances in different I/O banks to different Calibration IPs.
Connect PHY Lite IP instances in the same I/O bank to the same Calibration IP, but assign different Instance ID in the IP Parameter Editor to differentiate the base address of the instances (Rev B only).
Signal Name | Direction | Width | Description |
---|---|---|---|
fbr_axil_clk | Input | 1 | Clock |
fbr_axil_rst_n | Input | 1 | Reset |
fbr_axil_awaddr | Input | 27 | Write address |
fbr_axil_awvalid | Input | 1 | Write address valid |
fbr_axil_awready | Output | 1 | Write address ready |
fbr_axil_wdata | Input | 32 | Write data |
fbr_axil_wstrb | Input | 4 | Write strobes |
fbr_axil_wvalid | Input | 1 | Write valid |
fbr_axil_wready | Output | 1 | Write ready |
fbr_axil_bresp | Output | 2 | Write response |
fbr_axil_bvalid | Output | 1 | Write response valid |
fbr_axil_bready | Input | 1 | Response ready |
fbr_axil_araddr | Input | 27 | Read address |
fbr_axil_arvalid | Input | 1 | Read address valid |
fbr_axil_arready | Output | 1 | Read address ready |
fbr_axil_rdata | Output | 32 | Read data |
fbr_axil_rresp | Output | 2 | Read response |
fbr_axil_rvalid | Output | 1 | Read valid |
fbr_axil_rready | Input | 1 | Read Ready |
fbr_axil_awprot | Input | 3 | Write protection type |
fbr_axil_arprot | Input | 3 | Read protection type |