3.3.5.3. PMA Configuration Rules for OTN Mode

You can implement the OTN mode by using the following configuration settings in the GTS PMA/FEC Direct PHY IP:
  1. In the Common Datapath Options select OTN for the PMA configuration rules setting.
  2. Configure the PMA data rate to match specific OTN line bit rate you are using.
  3. Ensure that the reference clocks; transmitter (TX PLL reference clock) and receiver (RX CDR reference clock), are set to the correct frequency to support the OTN line rate.
The OTN mode requires following configuration:
Table 28.  OTN Configuration in the Common Datapath Options
Parameter Value
PMA Configuration Rules

OTN 18

No. of PMA Lanes

1

Datapath clocking mode PMA or System PLL
System PLL Frequency

322.265625-1000 MHz

OTN configuration rules support both System PLL and PMA clocking mode. If you select PMA clocking mode, this setting is not required.

PMA Mode Duplex
18 The OTN mode support is limited, contact Altera customer support to use this feature.