Intel® Agilex™ Configuration User Guide

ID 683673
Date 7/05/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.6.1. Prerequisites

To run this remote system update example, your system must meet the following hardware and software requirements:
  • You should create and download this example to the Intel® Agilex™ SoC Development Kit.
  • Your design should include the Mailbox Client Intel® FPGA IP that connects to a JTAG to Avalon® Master Bridge as shown the Platform Designer system. The JTAG to Avalon® Master Bridge acts as the remote system update host controller for your factory and application images.
  • In addition, your design must include the Reset Release Intel® FPGA IP. This component holds the design in reset until the entire FPGA fabric has entered user mode.
  • The ninit_done_reset and reset_bridge_1 components create a two-stage reset synchronizer to release the Mailbox Client Intel® FPGA IP and JTAG to Avalon Master Bridge Intel® FPGA IP from reset when the device configuration is complete and the device is in user mode.
  • The ninit_done output signal from Reset Release IP gates this reset by connecting to the ninit_done_reset in_reset pin.
  • The reset_in Reset Bridge Intel® FPGA IP provides a user mode reset. In this design, the exported resetpin connects to application logic.
  • Figure 73. Required Communication and Host Components for the Remote System Update Design Example