1.1. Compilation Overview
1.2. Using the Compilation Dashboard
1.3. Design Netlist Infrastructure
1.4. Using the Node Finder
1.5. Precompiled Component (PCC) Generation Flow
1.6. Analysis & Elaboration Flow
1.7. Design Synthesis
1.8. Design Place and Route
1.9. Incremental Optimization Flow
1.10. Fast Forward Compilation Flow
1.11. Full Compilation Flow
1.12. Compilation Monitoring Mode
1.13. Exporting Compilation Results
1.14. Integrating Other EDA Tools
1.15. Compiler Optimization Techniques
1.16. Synthesis Language Support
1.17. Synthesis Settings Reference
1.18. Fitter Settings Reference
1.19. Design Compilation Revision History
1.7.3.1. Registering the SDC-on-RTL SDC File
1.7.3.2. Applying the SDC-on-RTL Constraints
1.7.3.3. Inspecting SDC-on-RTL Constraints
1.7.3.4. Creating Constraints in SDC-on-RTL SDC Files
1.7.3.5. Using Entity-Based SDC-on-RTL Constraints
1.7.3.6. Types of SDC Files Used in the Quartus® Prime Software
1.7.3.7. Example: Using SDC-on-RTL Features
1.13.1. Exporting a Version-Compatible Compilation Database
1.13.2. Importing a Version-Compatible Compilation Database
1.13.3. Creating a Design Partition
1.13.4. Exporting a Design Partition
1.13.5. Reusing a Design Partition
1.13.6. Viewing Quartus Database File Information
1.13.7. Clearing Compilation Results
2.1. Factors Affecting Compilation Results
2.2. Strategies to Reduce the Overall Compilation Time
2.3. Reducing Synthesis Time and Synthesis Netlist Optimization Time
2.4. Reducing Placement Time
2.5. Reducing Routing Time
2.6. Reducing Static Timing Analysis Time
2.7. Setting Process Priority
2.8. Reducing Compilation Time Revision History
Visible to Intel only — GUID: mta1461787401608
Ixiasoft
1.13.2. Importing a Version-Compatible Compilation Database
Follow these steps to import a project compilation database into a newer version of the Quartus® Prime software:
Note: Designs exported from the Quartus® Prime Pro Edition software versions 23.2 or earlier cannot be imported into version 23.3 due to the new DNI database.
- Export a version-compatible compilation database for a complete design, as Exporting a Version-Compatible Compilation Database describes.
- In a newer version of the Quartus® Prime software, open the original project. Click Yes if prompted to open a project created with a different software version.
- Click Project > Import Design and specify the Quartus Database File. To remove previous results, turn on Overwrite existing project's databases
Figure 117. Import Design Dialog Box
- Click OK. When you compile the imported design, run only Compiler stages that occur after the stage the .qdb preserves, rather than running a full compilation. For example, if you import a version-compatible database that contains the synthesized snapshot, start compilation with the Fitter (Processing > Start > Start Fitter). If you import a version-compatible database that contains the final snapshot, start compilation with Timing Analysis (Signoff) (Processing > Start > Start Timing Analysis (Signoff)).
Related Information