Signal Name Type Width Default Description
fp32_mult_a[31:0] Input 32 Low Input data bus to the multiplier.
fp32_mult_b[31:0] Input 32 Low Input data bus to the multiplier.
fp32_result[31:0] Output 32 Output data bus from IP core.
fp32_chainout[31:0] Output 32 Connect these signals to the chainin signals of the next floating-point DSP IP core.
Table 111.  Clock, Enable, and Clear Signals
Signal Name Type Width Default Description
clk[0] Input 1 Low Input clock for all registers.
ena[2:0] Input 3 High Clock enable signals for all registers.

These signals are active-High.

clr[1:0] Input 2 Low These signals can be asynchronous or synchronous clear input signals for all registers. You may select the type of clear input signal using Type of clear signal parameter.

These signals are active-High.

For more information about clock enable restrictions for input registers, refer to the related information.

Table 112.  Exception Flag Signals
Signal Name Type Width Default Description
fp32_mult_overflow Output 1

This signal indicates if the FP32 multiplier result is a larger value compared to the maximum presentable value.

1: If the multiplier result is a larger value compared to the maximum representable value and the result is cast to infinity.

0: If the multiplier result is not larger than the maximum presentable value.

fp32_mult_underflow Output 1

This signal indicates if the FP32 multiplier result is a smaller value compared to the minimum presentable value.

1: If the multiplier result is a smaller value compared to the minimum representable value and the result is flushed to zero.

0: If the multiplier result is a larger than the minimum representable value.

fp32_mult_inexact Output 1

This signal indicates if the FP32 multiplier result is an exact representation.

1: If the multiplier result is:
  • a rounded value or
  • a smaller value compared to the minimum representable value or
  • a larger value compared to the maximum representable value.

0: If the multiplier result does not meet any of the criteria above.

fp32_mult_invalid Output 1

This signal indicates if the FP32 multiplier operation is ill-defined and produces an invalid result.

1: If the multiplier result is invalid and cast to qNaN.

0: If the multiplier result is not an invalid number.