Arria® V Avalon® Memory-Mapped (Avalon-MM) Interface for PCI Express* Solutions: User Guide
ID
683773
Date
10/25/2024
Public
1. Datasheet
2. Getting Started with the Avalon-MM Arria V Hard IP for PCI Express
3. Parameter Settings
4. Interfaces and Signal Descriptions
5. Registers
6. Reset and Clocks
7. Interrupts for Endpoints
8. Error Handling
A. PCI Express Protocol Stack
9. Design Implementation
10. Additional Features
11. Transceiver PHY IP Reconfiguration
12. Debugging
B. Frequently Asked Questions for PCI Express
C. Lane Initialization and Reversal
D. Document Revision History
2.1. Running Platform Designer
2.2. Generating the Example Design
2.3. Running a Gate-Level Simulation
2.4. Simulating the Single DWord Design
2.5. Understanding Channel Placement Guidelines
2.6. Generating Synthesis Files
2.7. Compiling the Design in the Quartus® Prime Software
2.8. Programming a Device
5.1. Correspondence between Configuration Space Registers and the PCIe Specification
5.2. Type 0 Configuration Space Registers
5.3. Type 1 Configuration Space Registers
5.4. PCI Express Capability Structures
5.5. Intel-Defined VSEC Registers
5.6. CvP Registers
5.7. 64- or 128-Bit Avalon-MM Bridge Register Descriptions
5.8. Programming Model for Avalon-MM Root Port
5.9. Uncorrectable Internal Error Mask Register
5.10. Uncorrectable Internal Error Status Register
5.11. Correctable Internal Error Mask Register
5.12. Correctable Internal Error Status Register
5.7.1.1. Avalon-MM to PCI Express Interrupt Status Registers
5.7.1.2. Avalon-MM to PCI Express Interrupt Enable Registers
5.7.1.3. PCI Express Mailbox Registers
5.7.1.4. Avalon-MM-to-PCI Express Address Translation Table
5.7.1.5. PCI Express to Avalon-MM Interrupt Status and Enable Registers for Endpoints
5.7.1.6. Avalon-MM Mailbox Registers
5.7.1.7. Control Register Access (CRA) Avalon-MM Slave Port
A.4.1. Avalon‑MM Bridge TLPs
A.4.2. Avalon-MM-to-PCI Express Write Requests
A.4.3. Avalon-MM-to-PCI Express Upstream Read Requests
A.4.4. PCI Express-to-Avalon-MM Read Completions
A.4.5. PCI Express-to-Avalon-MM Downstream Write Requests
A.4.6. PCI Express-to-Avalon-MM Downstream Read Requests
A.4.7. Avalon-MM-to-PCI Express Read Completions
A.4.8. PCI Express-to-Avalon-MM Address Translation for 32-Bit Bridge
A.4.9. Minimizing BAR Sizes and the PCIe Address Space
A.4.10. Avalon® -MM-to-PCI Express Address Translation Algorithm for 32-Bit Addressing
6.2.1.1. pclk
The transceiver derives pclk from the 100 MHz refclk signal that you must provide to the device.
The PCI Express Base Specification requires that the refclk signal frequency be 100 MHz ±300 PPM.
The transitions between Gen1 and Gen2 should be glitchless. pclk can be turned off for most of the 1 ms timeout assigned for the PHY to change the clock rate; however, pclk should be stable before the 1 ms timeout expires.
Data Rate |
Frequency |
---|---|
Gen1 |
250 MHz |
Gen2 |
500 MHz |
The CDC module implements the asynchronous clock domain crossing between the PHY/MAC pclk domain and the Data Link Layer coreclk domain. The transceiver pclk clock is connected directly to the Hard IP for PCI Express and does not connect to the FPGA fabric.