Intel Agilex® 7 Device Configuration via Protocol (CvP) Implementation User Guide

ID 683763
Date 12/04/2023
Public
Document Table of Contents

6.1.5.2. Setting Up the Correct MSEL Switch State

Select Active Serial x4 (Fast mode) for CvP operation.
Table 14.  MSEL Pin Settings for Active Serial x4 (Fast mode) Scheme of Intel Agilex® 7 Devices
Configuration Scheme MSEL[2:0]
AS (Fast mode - for CvP)6 001
6 To support AS fast mode, the VCCIO_SDM of Intel Agilex® 7 device must be fully ramped-up within 10ms to the recommended operating conditions. The delay between the device exiting POR and the SDM Boot-up is shorter for the fast mode compared to the normal mode. Therefore, AS fast mode is the recommended configuration scheme for CvP because the device can conform to the 120 ms of power stable to PCIe* link active time.