Intel® Agilex™ Variable Precision DSP Blocks User Guide

ID 683037
Date 11/17/2022
Public

A newer version of this document is available. Customers should click here to go to the newest version.

Document Table of Contents

5.5.7. Clear Signal

Table 52.  Clear Signal Tab
Parameter IP Generated Parameter Value Default Value Description
Type of clear signal clear_type

none

aclr

sclr

none

Specify the clear signal behavior for all registers in the fixed-point DSP block

  • none: Select to not use any clear signal.
  • aclr: Select to use asynchronous clear signal type for all registers.
  • sclr: Select to use synchronous clear signal type for all registers.
Enable clr0 for all input registers enable_clr0

No

Yes

No Select Yes to enable clr[0] signal for all input registers.
Enable clr1 for output and pipeline registers enable_clr1

No

Yes

No Select Yes to enable clr[1] signal for output and pipeline registers