Ixiasoft
2.1. Parsing Programming Files
2.2. Getting Device Information
2.3. Debugging QSPI Flash
2.4. QSPI Controller Settings and SFDP Values
2.5. Debugging Remote System Update
2.6. Voltage Sensor Monitoring
2.7. Temperature Sensor Monitoring
2.8. Hard Processor System (HPS) Cold Reset
2.9. Debug Log
2.10. SDM Mailbox Command
2.11. VR Diagnostic
2.12. VR Telemetry
Visible to Intel only — GUID: rvm1731488681246
Ixiasoft
2.11.1. Performing VR Diagnostic
Perform the VR diagnostic test by following the steps below.
- Click Hardware Setup and select the hardware setup to use for debugging.
- Click Load Device and select your device.
- Click Power Management tab.
Note: The Power Management tab is disabled if the selected device is not SDM-based.
- Click VR Diagnostic.
- Click Select All VR Diagnostic Test(s) to select all tests. To run specific tests, click the checkboxes for the tests you want to run.
Note: To run VADC crosscheck tests, the device must not be in user mode. VADC crosscheck tests are not supported in user mode and are disabled when the device enters user mode.
- Click Run Selected Test(s) to perform all the selected tests.
- Click Load Last Test Result to load the results of the last executed test.
- Passing tests are in green and with a checkmark symbol.
- Failing tests are in red and with an X symbol.
- Unsupported tests are in yellow with a question mark symbol.
- Click Clear to reset the test selection and results.
Figure 15. VR Diagnostic Results