AN 1009: Preserving Nios® II Processor IP for Quartus® Prime Version 24.1 and Newer
ID
839394
Date
3/17/2025
Public
1. AN 1009: Preserving Nios® II Processor IP for Quartus® Prime Version 24.1 and Newer
2. Preserving Nios® II Processor IP in Quartus® Prime Pro Edition Version 24.1 or Newer
3. Preserving Nios® II Processor IP in Quartus® Prime Standard Edition Version 24.1std or Newer
4. Archiving Projects
5. Document Revision History for AN 1009: Preserving Nios® II Processor IP for Quartus® Prime Version 24.1 and Newer
2.2.2.1. Handling Hardware Component in the Quartus® Prime Pro Edition Project
Ensure that the Nios® II project works successfully as a Quartus_1 project.
- Start Quartus_1 software and follow these steps:
- Open the Nios® II Quartus® Prime project.
- Verify that the QIP file is added into Project Navigator > Files.
- Verify that the QSYS file is removed from Project Navigator > Files.
Figure 17. QIP File in Project Files
- Start Quartus_2 software and follow these steps:
- Open the same Nios® II Quartus® Prime project.
- Ignore the recommended IP Upgrade.
- Do not perform Generate HDL.
- Proceed to compile the design in Quartus_2 software without regenerating HDL.
You have successfully migrated the discontinued Nios® II processor to a newer Quartus® Prime software (Quartus_2). Proceed to configure the design .SOF file into the FPGA devices.