1.1. Software and Hardware Requirements
1.2. Download and Install the Tutorial Design Files
1.3. Open the Tutorial Project
1.4. Creating Qsys Systems
1.5. Assemble a Hierarchical System
1.6. Viewing the Memory Tester System in Qsys
1.7. Compiling and Downloading Software to a Development Board
1.8. Debugging Your Design
1.9. Verifying Hardware in System Console
1.10. Simulating Custom Components
1.11. View a Diagram of the Completed System
1.4.1.1. Create a New Qsys System and Set up the Clock Source
1.4.1.2. Add a Pipeline Bridge
1.4.1.3. Add a Custom Pattern Generator
1.4.1.4. Add a PRBS Pattern Generator
1.4.1.5. Add a Two-to-One Streaming Multiplexer
1.4.1.6. Verify the Memory Address Map
1.4.1.7. Connect the Reset Signals
1.4.1.8. Save the System
1.4.2.1. Create a New Qsys System and Set Up the Clock Soource
1.4.2.2. Add a Pipeline Bridge
1.4.2.3. Add a Custom Pattern Checker
1.4.2.4. Add the PRBS Pattern Checker
1.4.2.5. Add a One-to-Two Streaming Demultiplexer
1.4.2.6. Verify the Memory Address Map
1.4.2.7. Connect the Reset Signals
1.4.2.8. Save the System
1.4.1.6. Verify the Memory Address Map
You control the system by accessing the memory locations allocated to each component within the subsystem. To ensure that the memory map of the system you create matches the memory map of other components, you must verify the base addresses for the data pattern generator system.
On the Address Map tab, verify that the entries in the Address Map table match the values in #mwh1411073373020/table_54ED964DACCD4D7480A621FF0B0D0E00. Red exclamation marks indicate that the address ranges overlap. Correct the base addresses, as appropriate, to ensure there are no overlapping addresses, and your map matches this tutorial’s guidelines.
Component | Address |
---|---|
custom_pattern_generator.csr | 0x00000400 – 0x0000040f |
custom_pattern_generator.pattern_access | 0x00000000 – 0x000003ff |
prbs_pattern_generator.csr | 0x00000420 – 0x0000043f |
two_to_one_st_mux.csr | 0x00000440 – 0x00000447 |