Fault Injection Intel® FPGA IP Core User Guide

ID 683254
Date 7/09/2019
Public
Document Table of Contents

1.7.4.1.2. Specifying an Error List From Prompt Mode

You can operate the Targeted Fault Injection feature interactively by specifying the number of faults to be 0 (-n 0). The Fault Injection Debugger presents prompt mode commands and their descriptions.
Prompt Mode Command Description
F Inject a fault
E Read the EMR
S Scrub errors
Q Quit

In prompt mode, you can issue the F command alone to inject a single fault in a random location in the device. In the following examples using the F command in prompt mode, three errors are injected.

F #3 0x12 0x34 0x56 0x78 * 0x9A 0xBC +

  • Error 1 – Single bit error at frame 0x12, bit 0x34
  • Error 2 – Uncorrectable error at frame 0x56, bit 0x78 (an * indicates a multi-bit error)
  • Error 3 – Double-adjacent error at frame 0x9A, bit 0xBC (a + indicates a double bit error)

F 0x12 0x34 0x56 0x78 *

One (default) error is injected:

Error 1 – Single bit error at frame 0x12, bit 0x34. Locations after the first frame/bit location are ignored.

F #3 0x12 0x34 0x56 0x78 * 0x9A 0xBC + 0xDE 0x00

Three errors are injected:

  • Error 1 – Single bit error at frame 0x12, bit 0x34
  • Error 2 – Uncorrectable error at frame 0x56, bit 0x78
  • Error 3 – Double-adjacent error at frame 0x9A, bit 0xBC
  • Locations after the first 3 frame/bit pairs are ignored