SDM I/O Hysteresis Specifications for Schmitt Trigger Input

Table 30.  SDM I/O Hysteresis Specifications for Schmitt Trigger Input

This device supports Schmitt trigger input on SDM I/O bank. A Schmitt trigger feature introduces hysteresis to the input signal for improved noise immunity, especially for signal with slow edge rate.

For specification status, see the Data Sheet Status table

Symbol Description Condition Min Typ Max Unit
VHYS Hysteresis for Schmitt trigger input VCCIO_SDM = 1.8 V 180 mV