Agilex™ 3 FPGAs and SoCs Device Data Sheet

ID 848370
Date 8/11/2025
Public
Document Table of Contents

HSIO OCT Without Calibration Resistance Tolerance Specifications

Table 16.  HSIO OCT Without Calibration Resistance Tolerance Specifications

This table lists the GPIO OCT without calibration resistance tolerance to PVT changes.

For specification status, see the Data Sheet Status table

Symbol Description Condition (V) Calibration Accuracy Unit
34-Ω and 40-Ω RS Internal series termination without calibration (34-Ω and 40-Ω setting) 1.3 V LVCMOS I/O standard 30 %
34-Ω and 40-Ω RS 30 Internal series termination without calibration (34-Ω and 40-Ω setting) 1.2 V LVCMOS, SSTL-12, HSTL-12, HSUL-12, and POD12 I/O standards 25 %
1.1 V LVCMOS, POD11, and LVSTL11 I/O standards 25 %
1.05 V LVCMOS and LVSTL105 I/O standards 25 %
34-Ω and 40-Ω RS Internal series termination without calibration (34-Ω and 40-Ω setting) 1.0 V LVCMOS I/O standard 30 %
50-Ω RT 30 Internal parallel termination without calibration (50-Ω setting) SSTL-12 and HSTL-12 I/O standards 25 %
POD11 and POD12 I/O standards 25 %
LVSTL11 and LVSTL105 I/O standards 25 %
100-Ω RD 31 Internal differential termination (100-Ω setting) True differential signaling I/O standard at VCCIO_PIO = 1.05 40 %
True differential signaling I/O standard at VCCIO_PIO = 1.1 40 %
True differential signaling I/O standard at VCCIO_PIO = 1.2 40 %
True differential signaling I/O standard at VCCIO_PIO = 1.3 40 %
100-Ω RD Internal differential termination (100-Ω setting) SLVS400 I/O standard 30 %
30 This specification applies to both single-ended and pseudo-differential I/O buffers.
31 This specification applies to VICM(DC) ≤ 1.3V. For VICM(DC) > 1.3V, a specification range of -60% to +40% applies.