1. Agilex™ 3 Clocking and PLL Overview
2. Agilex™ 3 Clocking and PLL Architecture and Features
3. Agilex™ 3 Clocking and PLL Design Considerations
4. Clock Control Altera™ FPGA IP Core
5. IOPLL FPGA IP
6. I/O PLL Reconfiguration
7. Document Revision History for the Clocking and PLL User Guide: Agilex™ 3 FPGAs and SoCs
2.2.1. PLL Features
2.2.2. PLL Usage
2.2.3. PLL Locations
2.2.4. PLL Architecture
2.2.5. PLL Control Signals
2.2.6. PLL Feedback Modes
2.2.7. Clock Multiplication and Division
2.2.8. Programmable Phase Shift
2.2.9. Programmable Duty Cycle
2.2.10. PLL Cascading
2.2.11. PLL Input Clock Switchover
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
2.2.13. PLL Calibration
6.1. Release Information for EMIF Calibration FPGA IP
6.2. Implementing HSIO I/O PLL Reconfiguration using EMIF Calibration IP
6.3. Implementing HVIO I/O PLL Reconfiguration
6.4. Reconfiguration Guideline for I/O PLLs
6.5. Axilite Interface Ports in the EMIF Calibration IP
6.6. Address Bus and Data Bus Settings
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
Agilex™ 3 devices support PLL reconfiguration and dynamic phase shift with the following features:
- PLL reconfiguration—I/O PLL can reconfigure a collection of parameters such as M, N, and C counter, bandwidth, and charge pump.
- Dynamic phase shift—I/O PLL can perform positive or negative phase shift. Able to shift multiple phase steps each time, where one phase step is equal to 1/8 of the VCO period. Dynamic Phase Shifts can only be performed through PLL reconfiguration.