2.2.6.4. Normal Compensation Mode
An internal clock in normal compensation mode is phase-aligned to the input clock pin. The external clock output pin has a phase delay relative to the clock input pin if connected in this mode. The Quartus® Prime Timing Analyzer reports any phase difference between the two. In normal compensation mode, the delay introduced by the clock network is fully compensated. Only one output clock can be compensated in normal compensation mode. The fabric-feeding PLL located within HVIO bank 6E, 6F/6G, and 6H does not support the compensation mode.
Figure 15. Example of Phase Relationship Between the PLL Clocks in Normal Compensation Mode