1. Agilex™ 3 Clocking and PLL Overview
2. Agilex™ 3 Clocking and PLL Architecture and Features
3. Agilex™ 3 Clocking and PLL Design Considerations
4. Clock Control Altera™ FPGA IP Core
5. IOPLL FPGA IP
6. I/O PLL Reconfiguration
7. Document Revision History for the Clocking and PLL User Guide: Agilex™ 3 FPGAs and SoCs
2.2.1. PLL Features
2.2.2. PLL Usage
2.2.3. PLL Locations
2.2.4. PLL Architecture
2.2.5. PLL Control Signals
2.2.6. PLL Feedback Modes
2.2.7. Clock Multiplication and Division
2.2.8. Programmable Phase Shift
2.2.9. Programmable Duty Cycle
2.2.10. PLL Cascading
2.2.11. PLL Input Clock Switchover
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
2.2.13. PLL Calibration
6.1. Release Information for EMIF Calibration FPGA IP
6.2. Implementing HSIO I/O PLL Reconfiguration using EMIF Calibration IP
6.3. Implementing HVIO I/O PLL Reconfiguration
6.4. Reconfiguration Guideline for I/O PLLs
6.5. Axilite Interface Ports in the EMIF Calibration IP
6.6. Address Bus and Data Bus Settings
2.2.13. PLL Calibration
I/O PLLs include both analog and digital blocks that require calibration to compensate for process, voltage, and temperature (PVT) variations. Agilex™ 3 uses the I/O manager to perform calibration routines.
There following are the main types of calibration:
- Power-up calibration—initiates automatically at device power-up and runs during device configuration.
- User calibration—if you perform dynamic reconfiguration or change the VCO clock frequency of the I/O PLL, you must perform user recalibration. You must enable the required calibration sequence.
- Static Phase Error Calibration—initiated after power up calibration to reduce phase error between reference clock and feedback clocks.
To successfully complete the calibration process, OSC_CLK_1 clocks and all reference clocks driving the I/O PLLs must be stable and free running at the start of FPGA configuration. If clock switchover is enabled, both reference clocks must be present for calibration. During user mode, when the I/O PLL does not detect a reference clock during configuration, calibration attempts continue periodically. After calibration has completed, the I/O PLL is locked automatically.