GTS AXI Multichannel DMA IP for PCI Express* User Guide
4.4.8. Control Shadow Interface (ss_ctrlshadow)
The control shadow interface brings out the settings of the various configuration register fields of the function. The interface provides update to primary control signals only. This interface should be connected to the corresponding Control Shadow Interface of the GTS AXI Streaming IP.
For information of this interface, refer to Control Shadow Interface.
Interface clock: axi_lite_clk
Signal Name | Direction | Description |
---|---|---|
ss_app_st_ctrlshadow_tvalid | Input | This signal is asserted for one clock cycle when there is an update to the register fields being monitored due to a Configuration Write performed by the Root Complex. The new settings of the register fields are available on the tdata bus. |
ss_app_st_ctrlshadow_tdata[39:0] | Input | When ss_app_st_ctrlshadow_tvalid is asserted, this signal provides the current settings of the register fields of the associated Function. [2:0] - Identifies the Physical Function Number of configuration register. [13:3] - Identifies the Virtual Function Number of the configuration register. [14] - Indicates information is for the Virtual Function implemented in the slot's Physical Function. [19:15] - Identifies the slot Number of the configuration register. [20] - Bus Master Enable [21] - MSI-X Mask [22] - MSI-X Enable [23] - Mem Space Enable [24] - ExpRom Enable [25] - TPH Req Enable [26] - ATS Enable [27] - MSI Enable [28] - MSI Mask [29] - Extended Tag [30] - 10 Bit Tag Req Enable [31] - PTM Enable [34:32] - MPS Size [37:35] - MRRS Size [38] - VF Enable [39] - Page Request Enable |