2.2.1. PLL Features
2.2.2. PLL Usage
2.2.3. PLL Locations
2.2.4. PLL Architecture
2.2.5. PLL Control Signals
2.2.6. PLL Feedback Modes
2.2.7. Clock Multiplication and Division
2.2.8. Programmable Phase Shift
2.2.9. Programmable Duty Cycle
2.2.10. PLL Cascading
2.2.11. PLL Input Clock Switchover
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
2.2.13. PLL Calibration
3.1. Guidelines: Clock Switchover
3.2. Guidelines: Timing Closure
3.3. Guidelines: Resetting the PLL
3.4. Guidelines: Configuration Constraints
3.5. Guidelines: I/O PLL Reconfiguration
3.6. Clocking Constraints
3.7. IP Core Constraints
3.8. Guideline: Achieving 5% Duty Cycle for fOUT_EXT ≥ 300 MHz Using tx_outclk Port from LVDS SERDES Intel® FPGA IP
6.1. Release Information for IOPLL Reconfig Intel® FPGA IP
6.2. Implementing I/O PLL Reconfiguration in the IOPLL Reconfig IP Core
6.3. IOPLL Reconfig IP Core Reconfiguration Modes
6.4. Avalon® Memory-Mapped Interface Ports in the IOPLL Reconfig IP Core
6.5. Address Bus and Data Bus Settings
6.6. Design Example
2.2.12. PLL Reconfiguration and Dynamic Phase Shift
There are two I/O bank I/O PLLs inside an I/O bank, one located at the top sub-bank and the other located at the bottom sub-bank. The two I/O bank I/O PLLs share the same IOPLL Reconfig IP ports in the I/O bank. Thus, only the I/O bank I/O PLL located in the top sub-bank can be implemented for PLL reconfiguration and dynamic phase shift. The fabric-feeding I/O PLL has its own IOPLL Reconfig IP ports and can always be reconfigured.
F-Series and I-Series devices support PLL reconfiguration and dynamic phase shift with the following features:
- PLL reconfiguration—I/O PLL can reconfigure the M, N, C counters, and bandwidth setting.
- Dynamic phase shift—I/O PLL can perform positive or negative phase shift. Able to shift multiple phase steps each time, where one phase step is equal to 1/8 of the VCO period.