7. Design Examples
This section describes the thermal design process using the Power and Thermal Calculator (PTC), with examples for each of the thermal modes in the PTC.
The PTC Thermal tab has three user modes:
- Find cooling solution for maximum junction temperature limit.
- Find available thermal margin for cooling solution.
- Find ambient temperature for specified cooling solution.
Examples for each mode are shown in the following topics.
For each example, you begin with a use case from either a Quartus® Prime output that acts as an input to the PTC, or a new case built in the PTC.
Each example assumes a small module with an Agilex™ 3 device with a heat sink attached, as depicted in the figure below. Additionally, no airflow is assumed over the heat sink. The assumed system includes a 10 layer PCB and the Agilex™ 3 device has a heat sink that measures 50mm x 50mm with 20mm tall fins.
Figure 11. Assumed PCB and Heat Sink

Note: The values in the following examples are for illustrative purposes only; they do not represent any real-world use case.