GTS Ethernet Intel® FPGA Hard IP User Guide: Agilex™ 3 FPGAs and SoCs
ID
848477
Date
4/07/2025
Public
A newer version of this document is available. Customers should click here to go to the newest version.
1. Overview
2. Install and License the GTS Ethernet Intel® FPGA Hard IP
3. Configure and Generate Ethernet Hard IP variant
4. Integrate GTS Ethernet Intel® FPGA Hard IP into Your Application
5. Simulate and Compile (MAC+PCS) Design Example
6. Simulate and Compile (MII PCS Only/PCS66 OTN/PCS66 FlexE) Design Example
7. Simulate and Compile SyncE Design Example
8. Simulate and Compile PTP1588 Design Example
9. Troubleshoot and Diagnose Issues
10. Appendix A: Functional Description
11. Appendix B: Configuration Registers
12. Appendix C: Document Revision History for the GTS Ethernet Intel® FPGA Hard IP User Guide: Agilex 3 FPGAs and SoCs
4.1. Implement Required Clocking
4.2. Implement Required Resets
4.3. Connect the Status Interface
4.4. Connect the MAC Avalon Streaming Client Interface
4.5. Connect the MII PCS Only Client Interface
4.6. Connect the PCS66 Client Interface – FlexE and OTN
4.7. Connect the Precision Time Protocol Interface
4.8. Connect the Ethernet Hard IP Reconfiguration Interface
4.4.1.1. Drive the Ethernet Packet to the TX MAC Avalon Streaming Client Interface with Disabled Preamble Passthrough
4.4.1.2. Drive the Ethernet Packet on the TX MAC Avalon Streaming Client Interface with Enabled Preamble Passthrough
4.4.1.3. Use i_tx_skip_crc to Control Source Address, PAD, and CRC Insertion
4.4.1.4. Assert the i_tx_error to Invalidate a Packet
4.4.2.1. Receive Ethernet Frame on the RX MAC Avalon Streaming Client Interface with Preamble Passthrough Disabled
4.4.2.2. Receive Ethernet Frame with Preamble Passthrough Enabled
4.4.2.3. Receive Ethernet Frame with Remove CRC bytes Disabled
4.4.2.4. Monitor Status and Errors on the RX MAC Avalon Streaming Client Interface
10.4.2. PTP User Flow
You must implement proper TX and RX data flows prior to sending PTP commands to the IP core and utilizing the timestamps.
Attention: The following flows depict pseudo-code meant for conceptual, illustrative purposes. For definitive software routines, consult the design example.
The figures below depict the TX and RX client flows described in the PTP TX Client Flow and PTP RX Client Flow sections.
Figure 71. PTP TX Client Flow
The figure displays the following events in PTP TX client flow. For more information, refer to PTP TX User Flow.
- A: Reading TX raw offset data from IP
- B: Calculating the TX offset value
- C: Writing calculated TX offset value to the IP