3.3.2. Mode and Common Datapath Options

Figure 29. GTS PMA/FEC Direct PHY Intel® FPGA IP Parameter Editor
Table 18.  Mode Parameter
Parameter Values Description
Direct PHY Operation Mode

Direct PHY General,

Reconfigurable PHY

Specifies the operation mode of the GTS PMA/FEC Direct PHY Intel® FPGA IP. In the Direct PHY General mode, the IP allows the PHY to operate in PMA Direct, PCS Direct, or FEC Direct modes. In the Reconfigurable PHY mode, the IP requires the GTS Dynamic Reconfiguration Controller Intel® FPGA IP in the design to switch between multiple data rates. Default value is Direct PHY General.

Note: The current release of the Quartus® Prime Pro Edition software does not support the Reconfigurable PHY setting.
Table 19.  Common Datapath Options Parameters
Parameter Values Description
PMA configuration rules

Basic,

SDI,

HDMI

Selects the protocol configuration rules for the GTS PMA. This parameter governs the rules for correct settings of individual parameters within the PMA.

Certain features of the PMA are available only for specific protocol configuration rules. This parameter is not a preset. You must still correctly set all other parameters for your specific protocol and application needs.

Default value is Basic.

Number of PMA lanes For TX Simplex and Duplex : 1, 2, 4

For RX Simplex : 1

Specifies the total number of PMA lanes in a bonded group. For example, if the value is 4, this means there are 4 PMA lanes bonded in the same group and share the same bonding clock. A value of 1 means there is no bonding. The number of PMA lanes is 1 when FEC is enabled.

Default value is 1.
Note: To use multiple lanes of RX simplex, you must instantiate the IP multiple times. Refer to Multilane RX Simplex Implementation for more details.

Datapath clocking mode

PMA

System PLL

Specifies whether the PMA parallel clock or System PLL is used to clock the TX/RX datapath.

Required to use System PLL when Enable FEC is on. Default value is System PLL.

System PLL frequency 32.5 to 1000 MHz
Specifies the system PLL clock frequency (MHz) and applicable if datapath clocking mode is selected as system PLL. Default value is 322.265625 MHz.
Note: You must ensure that the system PLL frequency and GTS System PLL Clocks Intel FPGA IP frequency is set to the same value if you are using the system PLL clocking mode.
PMA mode Duplex, TX Simplex and RX Simplex

Specifies the PMA operation mode. TX simplex and RX simplex can operate at independent rates at different PMA lanes. Default value is Duplex.

PMA data rate

10312.5 Mbps (default)

12500 Mbps (maximum)

Specifies the PMA data rate in units of Mbps (Mb/sec). Default value is 10312.5 Mbps.

PMA parallel clock frequency Data rate/PMA width Displays PMA parallel clock frequency which is PMA data rate divided by PMA interface width in MHz. Default value is Data rate / PMA Width.
PMA width 8, 10, 16, 20, 32

Specifies the PMA data width. Supported Data width is 8, 10, 16, 20 and 32 bit. Default value is 32

Provide separate interface for each PMA On/Off
When enabled, the GTS PMA/FEC Direct PHY Intel FPGA IP presents separate data and clock interfaces for each PMA lane, rather than a wide bus. Default value is Off.
Note: When the Enable FEC option is on, a separate interface is not available for each PMA by use of the Provide separate interface for each PMA option.
Enable refclock to core On/Off Enables the reference clock to FPGA core feature.
Note: This feature is not supported when the TX PLL cascade mode is enabled.
Table 20.  TX/RX Common PMA Options Parameters
Parameter Values Description
Loopback mode

disabled

parallel

reverse parallel

Selects the PMA loopback mode. Default value is disabled.