General-Purpose I/O User Guide: Agilex™ 3 FPGAs and SoCs
ID
847266
Date
8/04/2025
Public
1. Agilex™ 3 General-Purpose I/O Overview
2. Agilex™ 3 HSIO Banks
3. Agilex™ 3 HVIO Banks
4. Agilex™ 3 HPS I/O Banks
5. Agilex™ 3 SDM I/O Banks
6. Agilex™ 3 I/O Troubleshooting Guidelines
7. GPIO FPGA IP
8. Programmable I/O Features Description
9. Document Revision History for the General-Purpose I/O User Guide: Agilex™ 3 FPGAs and SoCs
2.5.1. I/O Standard Placement Restrictions for True Differential I/Os
2.5.2. Placement Restrictions for True Differential and Single-Ended I/O Standards in the Same or Adjacent HSIO Bank
2.5.3. VREF Sources and Input Standards Grouping
2.5.4. HSIO Pin Restrictions for External Memory Interfaces
2.5.5. RZQ Pin Requirement
2.5.6. I/O Standards Implementation Based on VCCIO_PIO Voltages
2.5.7. I/O Standard Selection and I/O Bank Supply Compatibility Check
2.5.8. Simultaneous Switching Noise
2.5.9. HPS Shared I/O Requirements
2.5.10. Clocking Requirements
2.5.11. Clock Restrictions for GPIO Interfaces
2.5.12. SDM Shared I/O Requirements
2.5.13. Unused Pins
2.5.14. VCCIO_PIO Supply for Unused HSIO Banks
2.5.15. HSIO Pins During Power Sequencing
2.5.16. Drive Strength Requirement for HSIO Input Pins
2.5.17. Maximum DC Current Restrictions
2.5.18. 1.05 V, 1.1 V, or 1.2 V I/O Interface Voltage Level Compatibility
2.5.19. Connection to True Differential Signaling Input Buffers During Device Reconfiguration
2.5.20. Implementing a Pseudo Open Drain
2.5.21. Allowed Duration for Using RT OCT
2.5.22. Single-Ended Strobe Signal Differential Pin Pair Restriction
2.5.23. Implementing SLVS-400 or DPHY I/O Standard with 1.1 V VCCIO_PIO
7.5.1.1. Input Path
The pad sends data to the input buffer, and the input buffer feeds the delay element. After the data goes to the output of the delay element, the programmable bypass multiplexers select the features and paths to use.
Figure 39. Simplified View of Single-Ended HSIO Input Path
Figure 40. Input Path Waveform in DDIO ModeThe actual timing relationship between different signals may vary depending on the specific design, delays, and phases that you specify for the clock.
Related Information