2.6.5. Shared Clocking Resources Between the GTS Transceiver Bank and HVIO Bank

For a corner GTS transceiver bank, which is located adjacent to the HVIO bank, some clock-to-core resources are shared. Refer to the GTS transceiver bank layout figures in the Building Blocks section to determine the corner transceiver banks based on the device you are using. Only the top left corner bank is not affected as it is adjacent to the HPS instead of a HVIO bank.

For each transceiver channel, there are four multiplexers that select the clock to be routed to the FPGA core. However, there are more than four sources to choose from both the GTS transceiver channel and also the HVIO bank, therefore not all of them can be used at the same time.
Figure 34. Shared Clocking Resources Between the GTS Transceiver Bank and HVIO Bank
Every channel in a GTS transceiver bank has a selection of five output clock options which are routed through these four multiplexers. These five output clocks are:
  1. tx_clkout
  2. tx_clkout2
  3. rx_clkout
  4. rx_clkout2
  5. Input reference clock to core

In the adjacent HVIO bank, several sources are also routed through these four multiplexers. They are:

  1. PLLREFCLK1
  2. PLLREFCLK2
  3. SOURCE_SYNC_CLK1
  4. SOURCE_SYNC_CLK2
Between these HVIO sources, the routing is spread across different channels of the adjacent transceiver bank. The following table lists which channel of the adjacent transceiver bank the HVIO sources are shared with.
Table 16.  HVIO Bank and GTS Transceiver Channel Sharing
HVIO Bank HVIO Pin GTS Transceiver Channel Number
5A PLLREFCLK1 2
5A PLLREFCLK2 2
5A SOURCE_SYNC_CLK1 0
5A SOURCE_SYNC_CLK2 0
5B PLLREFCLK1 3
5B PLLREFCLK2 3
6A PLLREFCLK1 3
6A PLLREFCLK2 3
6B SOURCE_SYNC_CLK1 0
6B SOURCE_SYNC_CLK2 0
6B PLLREFCLK1 2
6B PLLREFCLK2 2
6C PLLREFCLK1 0
6C PLLREFCLK2 0
6C SOURCE_SYNC_CLK1 2
6C SOURCE_SYNC_CLK2 2
6D SOURCE_SYNC_CLK1 3
6D SOURCE_SYNC_CLK2 3